Proposed Dosing of Ozone in Each Application Domain 1. Explanation of designation Feeding amount (additive): during application of ozone, fed ozone amount in unit quantity of some medium (such as water, air). [Unit:g/m3,mg/m3]Residual ozone conc

Proposed Dosing of Ozone in Each Application Domain 

1. Explanation of designation 

Feeding amount (additive): during application of ozone, fed ozone amount in unit quantity of some medium (such as water, air). [Unit:g/m3,mg/m3]

Residual ozone concentration: after feeding ozone which operates for a period of time, ozone content remained in unit cubage of this medium from consumed part of ozone and decomposed part of ozone. [Unit: mg/L,mg/m3]

Relation between PPM and mg/m3: PPM is unit of concentration, PPM=1/106 may be mass ratio, and may be cubage ratio.

Such as ozone concentration of 1PPM in air

Under normal station(0℃, 1 atmospheric pressure) is: 1PPM=2.14mg/m3

Under station of room temperature (25℃, 1 atmospheric pressure) is: 1PPM=2mg/m3

Such as ozone concentration of 1PPM in water

Under normal station(0℃, 1 atmospheric pressure) is: 1PPM=1mg/L

Half life: ozone is a kind of very active gas; it will compound to be oxygen by itself even if there is no other substance reacts with it. Therefore, ozone will attenuate by itself, the time for attenuating to be half period is called as half life.

Under normal temperature, half life of ozone in purified water is about 30 min.

Under normal temperature, half life of ozone in purified air is 45-60 min. 

2. Referenced Feeding Amount of Ozone in Water Treatment   

Type of application
Purpose of treatment
Feeding amount of ozone(g/m3)
Operation time of ozone (min)
Residual ozone concentration(mg/L)
Purified water treated with RO film
CODSterilization to reduce COD
1.5-3
5-10
0.3-0.5
Mineral water from deep well treated by ultrafiltration membrane
CODSterilization to reduce COD
2-4
5-10
0.3-0.5
Spring water treated by ultrafiltration membrane
CODSterilization to reduce COD
3-5
6-12
0.4-0.6
Treat district water supply with ozone and active carbon
CODSterilization to reduce COD
3-5
6-12
0.3-0.4
Sterilization treatment to production water supply
CODSterilization to reduce COD
4-6
6-12
0.5-0.6
Aquiculture
Reduce COD, reduce ammonia nitrogen and sterilization
1-2


3. Referenced Feeding Amount of Ozone in Air Treatment

Type of application
Purpose of treatment
Feeding amount of ozone (g/m3
Operation time of ozone (min)
concentration (PPM)
Instrument, utensil and vessel of medical treatment
  Disinfection and sterilization
50-100
60
20
Refrigeratory
  Disinfection and sterilization
15-25
60
6-10
Food processing workshop
Disinfection and sterilization
3-4
60
1-2
Food packaging workshop
  Disinfection and sterilization
30-40
60
10-15
Work clothing
  Disinfection and sterilization
25-50
60
10-20
General location
  Mildew prevention and fresh keeping
2.5-5
60
1-2
Bird egges
  Mildew prevention and fresh keeping
5-5.5
60
2-2.5
Banana
  Antisepsis and fresh keeping
5.5-8
60
2.5-3.5
Apple
  Antisepsis and fresh keeping
5
60
2
Vegetable (except leaf vegetable )
  Antisepsis and fresh keeping
2.5-3.5
60
1-1.5
Fish, aquatic products
  Antisepsis and fresh keeping
1.5-2.5
30
0.5-1
Fish processing workshop
  Deodorization and purification
7
30
3
Slaughter workshop
  Deodorization and purification
5-7
30
2-3
Refuse dump
Deodorization, purification and sterilization
25
30
10
Sewage disposal plant
  Deodorization, Purification
2.5-5
30
1-2
Mortuary
Deodorization,Sterilization
7
30
3